37 research outputs found

    The Speed of Waves : Measuring the velocity of pressure pulse waves traveling through peripheral blood vessels

    Get PDF
    Worldwide, cardiovascular diseases (CVDs) are the number one cause of death. Therefore, there is a strong and urgent need for an easy and quick prognostic indicator of this disease to support early diagnosis. The gold standard for determining arterial stiffness is measuring the pulse wave velocity (PWV), which is the speed of the pressure pulse traveling through the moving blood. The goal of this Ph.D. study was to develop and validate a non-invasive, photoplethysmography (PPG)-based device for peripheral measurement of the PWV on the finger. To this aim a novel sensor, called “Multi Photodiode Array” (‘MPA’), was designed for peripheral, non-invasive PWV measurements. Next, the MPA was shown to deliver reliable and accurate PWV measurements with a deviation below 3% within clinically relevant ranges. During the course of the research it was observed that the MPA positioning on the finger could strongly affect the quality of the PWV measurements. Therefore, an explorative study was conducted to find the optimal use condition of the MPA. The final clinical study showed that the MPA could be placed easily, rapidly, and consistently, irrespective of the volunteer whose PWV was measured, and delivered reliable and repeatable results. Overall, the results in this thesis suggest that the novel PPG-based MPA allows accurate and reliable PWV measurements within clinically relevant ranges. In the future, the MPA may substantially simplify PWV measurements and enable long-term monitoring of vascular health, which will contribute to improving prevention, diagnosis and treatment of CVD

    Comparison between pulse wave velocities measured using Complior and measured using Biopac

    Get PDF
    Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. The Biopac system is an easier to use alternative that uses ECG and simple optical sensors to measure the PWV between the heart and the fingertips, and thus extends a bit more to the peripheral vasculature compared to the Complior system. The goal of this study was to test under various conditions to what extent these systems provide comparable and correlating values. 25 Healthy volunteers, 20–30 years old, were measured in four sequential position: sitting, lying, standing and sitting. The results showed that the Biopac system measured consistently and significantly lower PWV values than the Complior system, for all positions. Correlation values and Bland–Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system

    Tissue perfusion and oxygenation to monitor fluid responsiveness in critically ill, septic patients after initial resuscitation: a prospective observational study

    Get PDF
    Fluid therapy after initial resuscitation in critically ill, septic patients may lead to harmful overloading and should therefore be guided by indicators of an increase in stroke volume (SV), i.e. fluid responsiveness. Our objective was to investigate whether tissue perfusion and oxygenation are able to monitor fluid responsiveness, even after initial resuscitation. Thirty-five critically ill, septic patients underwent infusion of 250 mL of colloids, after initial fluid resuscitation. Prior to and after fluid infusion, SV, cardiac output sublingual microcirculatory perfusion (SDF: sidestream dark field imaging) and skin perfusion and oxygenation (laser Doppler flowmetry and reflectance spectroscopy) were measured. Fluid responsiveness was defined by a ≥5 or 10 % increase in SV upon fluids. In responders to fluids, SDF-derived microcirculatory and skin perfusion and oxygenation increased, but only the increase in cardiac output, mean arterial and pulse pressure, microvascular flow index and relative Hb concentration and oxygen saturation were able to monitor a SV increase. Our proof of principle study demonstrates that non-invasively assessed tissue perfusion and oxygenation is not inferior to invasive hemodynamic measurements in monitoring fluid responsiveness. However skin reflectance spectroscopy may be more helpful than sublingual SDF

    Exogenous hydrogen sulfide gas does not induce hypothermia in normoxic mice

    Get PDF
    Hydrogen sulfide (H2S, 80 ppm) gas in an atmosphere of 17.5% oxygen reportedly induces suspended animation in mice; a state analogous to hibernation that entails hypothermia and hypometabolism. However, exogenous H2S in combination with 17.5% oxygen is able to induce hypoxia, which in itself is a trigger of hypometabolism/hypothermia. Using non-invasive thermographic imaging, we demonstrated that mice exposed to hypoxia (5% oxygen) reduce their body temperature to ambient temperature. In contrast, animals exposed to 80 ppm H2S under normoxic conditions did not exhibit a reduction in body temperature compared to normoxic controls. In conclusion, mice induce hypothermia in response to hypoxia but not H2S gas, which contradicts the reported findings and putative contentions

    An early diagnostic tool for diabetic peripheral neuropathy in rats

    Get PDF
    The skin's rewarming rate of diabetic patients is used as a diagnostic tool for early diagnosis of diabetic neuropathy. At present, the relationship between microvascular changes in the skin and diabetic neuropathy is unclear in streptozotocin (STZ) diabetic rats. The aim of this study was to investigate whether the skin rewarming rate in diabetic rats is related to microvascular changes and whether this is accompanied by changes observed in classical diagnostic methods for diabetic peripheral neuropathy. Computer-assisted infrared thermography was used to assess the rewarming rate after cold exposure on the plantar skin of STZ diabetic rats' hind paws. Peripheral neuropathy was determined by the density of intra-epidermal nerve fibers (IENFs), mechanical sensitivity, and electrophysiological recordings. Data were obtained in diabetic rats at four, six, and eight weeks after the induction of diabetes and in controls. Four weeks after the induction of diabetes, a delayed rewarming rate, decreased skin blood flow and decreased density of IENFs were observed. However, the mechanical hyposensitivity and decreased motor nerve conduction velocity (MNCV) developed 6 and 8 weeks after the induction of diabetes. Our study shows that the skin rewarming rate is related to microvascular changes in diabetic rats. Moreover, the skin rewarming rate is a non-invasive method that provides more information for an earlier diagnosis of peripheral neuropathy than the classical monofilament test and MNCV in STZ induced diabetic rats

    Small intra-individual variability of the preejection period justifies the use of pulse transit time as approximation of the vascular transit

    Get PDF
    Background Vascular transit time (VTT) is the propagation time of a pulse wave through an artery; it is a measure for arterial stiffness. Because reliable non-invasive VTT measurements are difficult, as an alternative we measure pulse transit time (PTT). PTT is defined as the time between the R-wave on electrocardiogram and arrival of the resulting pulse wave in a distal location measured with photoplethysmography (PPG). The time between electrical activation of the ventricles and the resulting pulse wave after opening of the aortic valve is called the pre-ejection period (PEP), a component of PTT. The aim of this study was to estimate the variability of PEP at rest, to establish how accurate PTT is as approximation of VTT. Methods PTT was measured and PEP was assessed with echocardiography (gold standard) in three groups of 20 volunteers: 1) a control group without cardiovascular disease aged 50 years, and 3) a group with cardiovascular risk factors, defined as arterial hypertension, dyslipidemia, kidney failure and diabetes mellitus. Results Per group, the mean PEP was: 1) 58.5 ± 13.0 ms, 2) 52.4 ± 11.9 ms, and 3) 57.6 ± 11.6 ms. However, per individual the standard deviation was much smaller, i.e. 1) 2.0-5.9 ms, 2) 2.8-5.1 ms, and 3) 1.6-12.0 ms, respectively. There was no significant difference in the mean PEP of the 3 groups (p = 0.236). Conclusion In conclusion, the intra-individual variability of PEP is small. A change in PT

    Assessing service quality of e-waste recycling: A case study from Putrajaya, Malaysia

    Get PDF
    The quality of recycling services will reflect the effectiveness of recycling performance further improvements. Putrajaya residents were selected as a study site to evaluate the recycling services and assess the ability of the services provided. Data were collected using a stratified random sampling of the households using the questionnaires that have been prior tested for reliability.The critical incident technique (CIT) was used to identify and analyse the satisfaction and dissatisfaction of recycling services. Five successful service constructs identified were a good feeling, secured environment, facilities and efficiency, educational and peer pressure.The paper highlights the form of recovery strategies undertaken by the authorities as perceived by the households
    corecore